Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Waste Management & Research
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Reimann, D. O.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Reimann, D. O.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Mercury Output From Garbage Incineration

Dieter O. Reimann

Director, Garbage Incineration and Power Heating Plant, City and County of Bamberg, Rheinstr. 6, D-8600 Bamberg, F.R.G.

Domestic garbage normally contains 3-4 g Hg tonne-1. Slag and filter dust from garbage incineration contain only small quantities of mercury, which are difficult to leach. About 80-90% of the mercury in the flue gas can be bound in the washings at condensation temperatures of 60-70 °C from a wet scrubber operated at pH 0.5-1.0 in the presence of surplus chloride. In the following neutralization of the flue gas washings with lime c. 30-40% of the mercury can be bound as oxide; the degree of Hg precipitation can be increased to 99% or more by adding small quantities of the precipitating agent trimercapto-s-triazine—TMT 15.

The Bamberg Model for controlled depositation of residual materials containing concentrated pollutants consists of mixing the filter dust with neutralization sludge to produce a solid and only slightly permeable product.

The usual concentrations of mercury in garbage incineration plants do not present a danger for the operating personnel. The mercury concentration in the residual material and emission is clearly dependent upon the percentage of used batteries, which can account for over 50% of the total mercury.

Key Words: Mercury limits in Germany • waste water • sewage sludge • workplace • emission • incineration • flue gas purification mercury emission • mercury gas • mercury dust • trimercapto-s-triazine/TMT 15 • Bamberg Model • mercury in batteries • mercury in domestic garbage.

Waste Management & Research, Vol. 4, No. 1, 45-56 (1986)
DOI: 10.1177/0734242X8600400107


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
Waste Manag ResHome page
D. O. Reimann
Treatment of Waste Water From Refuse Incineration Plants
Waste Management Research, January 1, 1987; 5(1): 147 - 157.
[Abstract] [PDF]


Home page
Waste Manag ResHome page
A. D. Shendrikar and D.S. Ensor
Critical Review: Measurement of Mercury Combustion Aerosols in Emissions From Stationary Sources
Waste Management Research, January 1, 1986; 4(1): 75 - 93.
[Abstract] [PDF]