Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Waste Management & Research
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Gounon, J.
Right arrow Articles by Milhau, A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Gounon, J.
Right arrow Articles by Milhau, A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Analysis of Inorganic Pollutants Emitted By the City of Paris Garbage Incineration Plants

J. Gounon

A. Milhau

Chief Engineer, Ville de Paris, Direction de la Propreté, Section du Traitment des Ordures Ménageres, 57 Boulevard de Sébastopol, 75001 Paris, France

The City of Paris has to eliminate 2 million tons of household garbage each year, mainly by incineration with heat recovery, and while doing so wishes to participate fully in the international struggle against acid rain and heavy metal pollution. The City has decided to determine precisely the atmospheric effluent emanating from present industrial plants, and to this effect a comprehensive monitoring campaign was undertaken. The analysis, unique in France because of the exhaustive nature and size of the facilities deployed for the purpose, covered many parameters.

The results are that (1) the HC 1 gas concentration in smoke, about 1000 mg m-3, contributing almost one-half of the fallout, was observed at a rate of 10 µg m -3 at 5 km from the plant; and (2) the total heavy metals concentration in a modern plant is about 4 mg m-3 but, excluding Zn, less than 2 mg m-3. Analyses are given for each components Pb, Cd, Zn, Cr, Cu, Ni, Ba, Co, Ag and Hg.

Key Words: Incineration • air pollution • heavy metals • mercury • cadmium • lead • hydrogen chloride • sampling gear • standard measurement methods.

Waste Management & Research, Vol. 4, No. 1, 95-104 (1986)
DOI: 10.1177/0734242X8600400111


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?