| Sign In to gain access to subscriptions and/or personal tools. |
Emissions of Organic Micropollutants From Discontinuously Operated Municipal Waste IncineratorsCenter for Industrial Research, Blindern, Oslo, Norway
Center for Industrial Research, Blindern, Oslo, Norway
Center for Industrial Research, Blindern, Oslo, Norway
Norwegian Institute of Air Research, Lillestrom, Norway
Center for Industrial Research, Blindern, Oslo, Norway The emission of particles and organic micropollutants (PAH, PCDD and PCDF) was measured from three intermittently operated municipal waste incinerators of medium size. The mutagenicity of the stack gas samples were measured as well. The results show a good agreement between the PAH emitted and the mutagenicity in the stack gases, but none of these parameters correlate with the PCDD/PCDF content.
Key Words: Incineration Municipal waste Air pollution PAH PCDD PCDF Mutagenicity Particles Incineration periods Medium-sized plants.
Waste Management & Research, Vol. 8, No. 1,
193-201 (1990) |
|||